Blocks that Support Fault Modeling
Each table lists each block that supports faults, the library path for that block, the fault subelement paths, and whether the block contains fault subelements that depend on parameter settings. You can use these when you interact with block faults from the MATLAB command line.
The fault subelement path is the location in a Simscape model where you can add a fault. Each block represents a model element with one or more subelements. Some of these subelement paths are only available for certain parameter configurations. See the block reference page for the specific block to determine the parameter dependencies for a given fault subelement.
Simscape Battery
Block Name | Fault Subelement Path | Parameter Dependency |
---|---|---|
Battery Equivalent Circuit (Simscape Battery) |
| Yes |
Simscape Driveline
Block Name | Fault Subelement Path | Parameter Dependency |
---|---|---|
Band Brake (Simscape Driveline) | /Belt tension | No |
Bearing (Simscape Driveline) | /Damping | No |
Cone Clutch (Simscape Driveline) | /Clutch | No |
Disc Brake (Simscape Driveline) | /Brake pressure | No |
Disc Friction Clutch (Simscape Driveline) | /Friction | No |
Double-Shoe Brake (Simscape Driveline) | /Belt tension | No |
Loaded-Contact Rotational Friction (Simscape Driveline) | /Friction | No |
Loaded-Contact Translational Friction (Simscape Driveline) | /Friction | No |
Rotational Damper (Simscape Driveline) | /Damping | No |
Simple Gear (Simscape Driveline) | /Gear | Yes |
Translational Damper (Simscape Driveline) | /Damping | No |
Simscape Fluids
Block Name | Fault Subelement Path | Parameter Dependency |
---|---|---|
2-Way Directional Valve (IL) (Simscape Fluids) |
| No |
3-Way Directional Valve (IL) (Simscape Fluids) | 3-Way Directional Valve Area | No |
4-Way 2-Position Directional Valve (IL) (Simscape Fluids) | 4-Way 2-Position Directional Valve Area | No |
4-Way 3-Position Directional Valve (IL) (Simscape Fluids) | 4-Way 3-Position Directional Valve Area | No |
Check Valve (IL) (Simscape Fluids) | Check Valve Area | No |
Orifice (IL) (Simscape Fluids) | Orifice Area | No |
Pressure Compensator Valve (IL) (Simscape Fluids) | Pressure Compensator Valve Area | No |
Pressure Relief Valve (IL) (Simscape Fluids) | Pressure Relief Valve Area | No |
Pressure-Reducing 3-Way Valve (IL) (Simscape Fluids) |
| No |
Pressure-Reducing Valve (IL) (Simscape Fluids) |
| Yes |
Fixed-Displacement Motor (IL) (Simscape Fluids) |
| No |
Fixed-Displacement Pump (IL) (Simscape Fluids) |
| No |
Fixed-Displacement Motor (TL) (Simscape Fluids) |
| No |
Fixed-Displacement Pump (TL) (Simscape Fluids) |
| No |
Fixed-Displacement Pump (2P) (Simscape Fluids) |
| No |
Orifice (TL) (Simscape Fluids) | Orifice Area | No |
2-Way Directional Valve (TL) (Simscape Fluids) | 2-Way Directional Valve Area | No |
3-Way Directional Valve (TL) (Simscape Fluids) | 3-Way Directional Valve Area | No |
4-Way 2-Position Directional Valve (TL) (Simscape Fluids) | 4-Way 2-Position Directional Valve Area | No |
4-Way 3-Position Directional Valve (TL) (Simscape Fluids) | 4-Way 3-Position Directional Valve Area | No |
Check Valve (TL) (Simscape Fluids) | Check Valve Area | No |
Pressure Reducing Valve (TL) (Simscape Fluids) |
| Yes |
Pressure Relief Valve (TL) (Simscape Fluids) | Pressure Relief Valve Area | No |
Pressure Compensator Valve (TL) (Simscape Fluids) | Pressure Compensator Valve Area | No |
Simscape Electrical
Block Name | Fault Subelement Path | Parameter Dependency |
---|---|---|
Compound Motor (Simscape Electrical) |
| No |
DC Motor (Simscape Electrical) |
| Yes |
RC Servo (Simscape Electrical) | /Servo | No |
Magnetic Rotor (Simscape Electrical) | /Rotor poles | No |
Motor & Drive (System Level) (Simscape Electrical) | /Open circuit | No |
Capacitor (Simscape Electrical) | /Capacitor | No |
Constant Current Load (Simscape Electrical) | /Open circuit | No |
Constant Current Load (Three-Phase) (Simscape Electrical) | /Open circuit | No |
Constant Power Load (Simscape Electrical) | /Open circuit | No |
Constant Power Load (Three-Phase) (Simscape Electrical) | /Open circuit | No |
Diffusion Resistor (Simscape Electrical) | /Resistance | No |
Dynamic Load (Simscape Electrical) | /Open circuit | No |
Dynamic Load (Three-Phase) (Simscape Electrical) | /Open circuit | No |
RLC (Three-Phase) (Simscape Electrical) | /Branch | No |
Delta-Connected Load (Simscape Electrical) | /Connection | Yes |
Wye-Connected Load (Simscape Electrical) | /Connection | Yes |
Incandescent Lamp (Simscape Electrical) | /Open circuit | No |
Inductor (Simscape Electrical) | /Inductor | No |
Transmission Line (Three-Phase) (Simscape Electrical) | /Section interface | Yes |
Resistor (Simscape Electrical) | /Resistance | No |
Mutual Inductor (Simscape Electrical) | /Mutual inductor | No |
Winding (Simscape Electrical) | /Winding | No |
DC-DC Converter (Simscape Electrical) | /Open circuit | No |
Diode (Simscape Electrical) | /Diode | No |
Gate Driver (Simscape Electrical) | /State | No |
Half-Bridge Driver (Simscape Electrical) | /State | No |
N-Channel MOSFET (Simscape Electrical) | /NMOS | No |
P-Channel MOSFET (Simscape Electrical) | /PMOS | No |
SPMT Switch (Simscape Electrical) | /Stuck throw | No |
See Also
Introduction to Simscape Faults | Analyze a DC Armature Winding Fault | Create and Manage Conditionals