Simulink error using Data Store Read/Write

36 views (last 30 days)
I get the following error when I compile my model:
The block 'Util/Common/ReadToggled_LampTest' is reading from the data store 'Util/Common/Toggled_LampTest' before one or more blocks have written to this entire region of memory at time 0.0
I search the internet with different versions of the error that I got and I didn’t see anything on the error that I currently have. What do I need to do to fix this error without setting my configuration parameters from error to warning?

Accepted Answer

Kaustubha Govind
Kaustubha Govind on 10 Oct 2012
Have you verified that 'Util/Common/ReadToggled_LampTest' is indeed not reading from 'Util/Common/Toggled_LampTest' before it's been written to? You can look at the block sorted order to see if 'Util/Common/ReadToggled_LampTest' is executing before the block that writes to 'Util/Common/Toggled_LampTest' does.
  2 Comments
Kaustubha Govind
Kaustubha Govind on 11 Oct 2012
Lucas: As the documentation that I linked to says "Simulink honors the block priorities that you specify unless they violate data dependencies" - so I think restructuring the model is the right way to go.

Sign in to comment.