What is the difference between using the 2-Port Constant Volume Chamber and 3-Port Constant Volume Chamber block with three gas domain signals?
Accepted Answer
MathWorks Support Team
on 18 Jan 2024
Edited: MathWorks Support Team
on 1 Mar 2024
The notable differences between the use of these two blocks are the equations that describe mass balance and energy balance, and the ability to define cross sectional port areas.The 2-Port Constant Volume Chamber (G) block has fewer terms than the 3-Port Constant Volume Chamber (G) block. When using three gas signals, this does not matter two much but just be aware of the differences in equations.Please run the below command in the MATLAB R2018b command window to get the release specific documentation
web(fullfile(docroot, 'physmod/simscape/ref/2portconstantvolumechamberg.html'))
Please run the below command in the MATLAB R2018b command window to get the release specific documentation
web(fullfile(docroot, 'physmod/simscape/ref/3portconstantvolumechamberg.html'))
Please be aware of connecting two gas signals when using the 2-Port Constant Volume Chamber (G) block. This block does not allow you to control the cross sectional port area for each individual gas signal. The replacement of systems with different cross sectional areas with a 2-Port Constant Volume Chamber may cause differences in results. This can affect flow rates.