How to Stop Simulation in Test Sequence Block
32 views (last 30 days)
Show older comments
Hello Mathworks-Team,
I am currently trying out Simulink Test and I've got a question about the Test Sequence Block. Is there any opportunity to stop the simulation, if a specified state is reached. I tried
set_param(ModelName, 'simulationcommand', 'stop')
but this doesn't work. The ModelName can't be read from workspace because it's a char array and Simulink Test only supports numerical or logical types.
1 Comment
Sai Vempati
on 8 Nov 2018
How to stop a sweep rate input signal if a required freq is achieved! im unable to Stop Simulation with this stop block if a specified state is reached
my seems to be similar ! Thanks in advance for everyone
Sai
Answers (4)
Dave
on 27 Jan 2021
This should work when not using accellerated mode:
coder.extrinsic("set_param");
set_param(bdroot, 'simulationcommand', 'stop')
Young Ma
on 2 Aug 2017
Hi Patrick,
I understand from your description that you want to stop the simulation when a specific state is reached in Test Sequence block. This is not supported yet in R2017a. I'll communicate this with the relevant staff and hopefully this feature will be available in a future release.
A workaround for this is to use 'Stop Simulation' block, which is documented in the following link: https://www.mathworks.com/help/simulink/slref/stopsimulation.html?
You can generate an non-zero output from Test Sequence block when a specific state is reached and feed this to the 'Stop Simulation' block so you can stop the simulation.
2 Comments
Jonas Londschien
on 4 Oct 2018
Edited: Jonas Londschien
on 4 Oct 2018
Hello,
is this feature already added in 2018b? I am also interested in it, as an error will fail the test, and a extra block is annoying in a programmatic test created test sequence.
Sebastian Castro
on 15 Oct 2015
Edited: Sebastian Castro
on 15 Oct 2015
You can use the error function inside the step you want. This will stop the simulation and output a custom error message.
error('My error message')
Another alternative is, when you reach the state, to change the value of an output signal from false to true. Then, connect this signal to a Stop Simulation block.
- Sebastian
Todd
on 4 Mar 2022
One method is to add an output signal that drives a Simulation Stop block.
0 Comments
See Also
Categories
Find more on Inputs in Help Center and File Exchange
Products
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!