I have logged a signal from simulink to workspace in timeseries format and got 317 samples of that signal. Can i increase the number of samples i get or the sampling rate?

5 views (last 30 days)
I tried changing start time and end time in this, so that i can get 317 samples in reduced interval thus accuracy of the logged signal can be increased.But, when i run the code again the applied changes were not taken.
Is it even possible to change sampling rate because,this approximated signal causing cumulative error in my code.
  3 Comments
Paul
Paul on 13 Jan 2024
How exactly is the signal being logged? Using a To Workspace block?
How exactly do you get that "Define Uniform Time Vector" dialog box?
A Lumbini
A Lumbini on 14 Jan 2024
Yes i used To Workspace block
and by clicking on the logged signal the above shared screenshot appeared and there is a Uniform Time Vector box

Sign in to comment.

Answers (1)

Paul
Paul on 14 Jan 2024
More samples of the logged signal can be collected by settng the Sample Time of the To Workspsace block to whatever sample time is needed. The sample time will have to be consistent with the step size of the simulation solver. There will not be a problem if the solver is variable step.