Numerical error in simulink
Show older comments

Often, I've encountered errors like the one above when using Simulink's add or product block.
When I check each signal, I don't see any division by 0. Sometimes it's just a matter of replacing the + with a -. What is the problem?
Accepted Answer
More Answers (1)
Walter Roberson
on 20 Nov 2023
Edited: Walter Roberson
on 20 Nov 2023
0 votes
When the error is at time 0, as is the case in your example, then the problem is almost always incorrect initial values.
Consider for example if you have a derivative block. At time 0, no time has elapsed so far so the "natural" outcome right at time 0 is either 0 change divided by 0 seconds (0/0 giving NaN) or else some finite change divided by 0 seconds (giving +/- infinity). So for derivative blocks and similar it is crucial that you define the initial conditions.
Likewise if you have any calculation in your model that divides something by clock time, the calculation is in trouble at time 0.
1 Comment
Paul
on 20 Nov 2023
The error occurred at T = 0.128, not T = 0, so it's not an issue with initial conditions at the start of the simulation.
Also, the Derivative Block does not work that way; it always outputs 0 as its initial output. As far as I know, the Derivative block doesn't have an initial condition to specify.