Setting Aging parameters in generic battery model (battery mask)
9 views (last 30 days)
Show older comments
Hi, Can anyone help me with setting aging parameters in generic battery model?
- Capacity at EOL (End Of Life) (Ah)
- Internal resistance at EOL (Ohms)
- Cycle life at 100 % DOD, Ic and Id (Cycles)
- Cycle life at 25 % DOD, Ic and Id (Cycles)
- Cycle life at 100 % DOD, Ic and Idmax (Cycles)
- Cycle life at 100 % DOD, Icmax and Id (Cycles)
In the documentation, they described how to set discharge and temperature related parameters from battery datsheet. But I am not finding mentioned aging paramters in the datasheet.
2 Comments
Christine Li
on 21 Apr 2023
Hi Jarin,
What is the vendor and part number of the battery you are using? If you are using this Table-based Battery block, you can parameterize the battery model with pre-built data sheet from many vendors. Here is the list of Pre-Parameterized Components. If the battery you are using is not listed, the alternative method is to use paramter esimator app to esimate the unknown parameters for battery. Please check this short video: Modeling Batteries Using Simulink and Simscape.
Answers (1)
Javier Gazzarri
on 26 Jul 2023
Hello Jarin,
Aging parameters are typically difficult to find in datasheets and sometimes you need to cycle the battery to find them. Sometimes this is information a battery supplier may be able and willing to provide.
Depending on the type of analysis you are doing, you may also set these parameters according to a warranty claim or worst case scenario, and perform simulations of a generic battery use to determine whether the EOL condition is reached after a certain amount of usage.
Please let me know if this is of any help.
Javier
0 Comments
See Also
Categories
Find more on Get Started with Simscape Battery in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!