How to change the transfer function variable in simulink during simulation time
Show older comments
Hi,
I have a Simulink model, where I need to change the transfer function coefficient during simulation run time. For example the TF is (1/1+sRC). Here R and C values need to change during run time. How to do that? Problem here is that the R value is calculated with the load current, that is (output voltage)/(load current). So I know the load current variation by calculating the R values. If anyone knows how to change the TF coefficient during runtime please help me. Thanks in advance.
Answers (1)
Paul
on 7 Sep 2022
0 votes
Hi Swasthik,
If I understand correctly, the R and C values are changing dynamically. Just use blocks (integrators, subtraction, product, etc.) to implement the first order differential equation explicitly. The Transfer Function block is intended to be used with fixed parameters.
4 Comments
Swasthik Baje Shankarakrishna Bhat
on 8 Sep 2022
Sam Chak
on 8 Sep 2022
can be expressed in the 1st-order Differential equation form:
If R is a function of the state
, then using the Integrator block and some fundamental blocks, you can construct the signal flow according to this Integral equation:
Swasthik Baje Shankarakrishna Bhat
on 19 Sep 2022
Sam Chak
on 19 Sep 2022
Categories
Find more on General Applications in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!