Zynq workflow error in step 4.2

12 views (last 30 days)
zyx851
zyx851 on 11 May 2022
Commented: zyx851 on 11 May 2022
When I try to run foc demo on zynq, there has been an error in step 4.2.
I have tried MATLAB R2022a, R2021b, R2020b and R2019b, they all have this problem.
  1 Comment
zyx851
zyx851 on 11 May 2022
### ++++++++++++++ Task Generate Software Interface ++++++++++++++
### Generating new Zynq Software Interface model: gm_focZynqHdl_interface
### No driver block was generated for port(s) "IP_ADC_A_Count" mapped to interface "IP_ADC_PhaseCurrentA" in the software interface model.
### No driver block was generated for port(s) "IP_ADC_B_Count" mapped to interface "IP_ADC_PhaseCurrentB" in the software interface model.
### No driver block was generated for port(s) "IP_Encoder_Index_Found" mapped to interface "IP_ENC_IndexFound" in the software interface model.
### No driver block was generated for port(s) "IP_Encoder_Count" mapped to interface "IP_ENC_Count" in the software interface model.
### No driver block was generated for port(s) "IP_Encoder_Count_Per_Revolution" mapped to interface "IP_ENC_Count_Per_Revolution" in the software interface model.
### No driver block was generated for port(s) "IP_Encoder_A_Leads_B" mapped to interface "IP_ENC_A_Leads_B" in the software interface model.
### No driver block was generated for port(s) "IP_Inverter_Enable" mapped to interface "IP_PWM_Enable" in the software interface model.
### No driver block was generated for port(s) "IP_PWM_Counter_Max" mapped to interface "IP_PWM_CounterMax" in the software interface model.
### No driver block was generated for port(s) "IP_PWM_A_Compare" mapped to interface "IP_PWM_CompareA" in the software interface model.
### No driver block was generated for port(s) "IP_PWM_B_Compare" mapped to interface "IP_PWM_CompareB" in the software interface model.
### No driver block was generated for port(s) "IP_PWM_C_Compare" mapped to interface "IP_PWM_CompareC" in the software interface model.
### No driver block was generated for port(s) "IP_PWM_Dead_Time_Count" mapped to interface "IP_PWM_DeadTimeCount" in the software interface model.
Executing custom callback plugin_gm_config for model focZynqHdl.
Dot indexing is not supported for variables of this type.
Error in zynqMotcon2.referenceDesignVivado.plugin_gm_config (line 156)
delete(topLevelLines.Inport);
Error in hdlturnkey.backend.ModelGeneration/customGMConfig
Error in hdlturnkey.backend.ModelGenerationECoder/configureTIFDUT
Error in hdlturnkey.backend.ModelGenerationECoder/generateModelWithoutLibraryBlock
Error in hdlturnkey.backend.ModelGeneration/generateModel
Error in hdlturnkey.TurnkeyDriver/generateInterfaceModel
Error in hdlturnkey.ip.IPDriver/runSWInterfaceGen
Error in downstream.DownstreamIntegrationDriver/runSWInterfaceGen
Error in hwcli.runWorkflow
Error in hdlcoder.runWorkflow (line 27)
hwcli.runWorkflow( varargin{:} );
Error in task.t5_generateBitstreamAndInterfaceBlock (line 177)
hdlcoder.runWorkflow('focZynqHdl', hWC);

Sign in to comment.

Answers (1)

Kiran Kintali
Kiran Kintali on 11 May 2022
Edited: Kiran Kintali on 11 May 2022
This is an unepxected error issue. Please contact tech support for a solution and the next steps.

Categories

Find more on Deployment, Integration, and Supported Hardware in Help Center and File Exchange

Tags

Products


Release

R2022a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!