Can you 'run all' in a signal builder programmatically?
Hi Collin, If you are using Simulink Design Verifier product, running all testcases programmatically can be accomplished by u...
meer dan 6 jaar ago | 0
How to apply constraints on test signals being generated by Design Verifier?
Hi Tushar, The signals in the test cases can be constrained by using ‘Test Condition’ block from Simulink Design Verifier lib...
meer dan 6 jaar ago | 1
| accepted
Problem with setting a model parameter for Design Verifier
The parameters related to Simulink Design Verifier can be changed programmatically using sldvoptions. For example: opts ...
meer dan 6 jaar ago | 0
| accepted
I am getting following error while using Simulink.BlockDiagram.createSubsystem. I am using MATLAB 2015b.
Hi Prasanna, The API used to create a subsystem in 2015b version is 'Simulink.BlockDiagram.createSubSystem'. Here is the docu...
meer dan 6 jaar ago | 1