Hi,
How can I build a counter that starts to count from 0 only after a specific start signal and stops after an other signal (by simulink) ?
0 Comments
Answers (1)
Kaustubha Govind
on 16 Jun 2011
Perhaps you could use the Counter Free-Running block inside an Enabled Subsystem and construct the enable signals based on your other two signals?
2 Comments
Kaustubha Govind
on 16 Jun 2011
Are you saying that the subsystem starts executing at the beginning of simulation? No - it depends on whenever the enable signals goes active. So you can construct your enable signal such that the counter only executes for the duration that you want it to.