SimPower Systems (PSB): discrete analysis

3 views (last 30 days)
Leif
Leif on 19 Jul 2013
Answered: Sabin on 20 Dec 2022
When using Simulink with SimPower Systems blockset (PSB) you have to use a block called "powerGUI".
There you can specify a sample time, when simulation type is discrete.
Still you can choose another sample time or even continuous solver in "normal" simulink 'Model Configuration Parameter' window.
Will there be a cont. or discrete analysis ? What's the difference between those two options ? Why do I need them both ?

Answers (1)

Sabin
Sabin on 20 Dec 2022
This is like using a Simulink discrete block while setting the global solver to variable-step. The power systems part would be discrete if a discrete rate is selected. But some parts of the model might still run in continuous time (controlled by the global solver) if continuous Simulink blocks are used in the model.

Categories

Find more on Electrical Sensors in Help Center and File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!