Ive had this error come up and was wondering if I could get some help on it. The error comes as i try generating my simulink model via matlab code as such:
Each physical network must be connected to exactly one Solver Configuration block.
There is no Solver Configuration block connected to Physical Network with the
following blocks: 'ballValveModel/HydRef1'
'ballValveModel/HydSource'
'ballValveModel/SPSConv'
As the error says, should i be adding a solver block for each of the added blocks? This dosent sound like the right solution. Any help would be great.
0 Comments
Answers (1)
Surya Talluri
on 1 Sep 2020
I understand that you are getting the because you didn’t add the solver configuration block to your physical network.
Each physical network represented by a connected Simscape block diagram requires solver settings information for simulation. The Solver Configuration block specifies the solver parameters that your model needs before you can begin simulation.
add_block('nesl_utility/Solver Configuration', 'ballValveModel/solver');
You can refer to following documentation for further understanding on Simscape and Solver configuration: