AC/DC Three-Level PWM Converter

5 views (last 30 days)
NN
NN on 29 Jun 2020
Answered: Mohsen Aleenejad on 30 Jul 2020
AC/DC Three-Level PWM Converter is an example matlab file and why this file doesnt not work for negative active power reference.Does it needs to change the initial conditions set and if so how to do that ?
  10 Comments
NN
NN on 30 Jun 2020
Thank you Mohsen.I i wll surely check these otpions
Mohsen Aleenejad
Mohsen Aleenejad on 30 Jun 2020
I am happy that I could help.
Good Luck.

Sign in to comment.

Answers (1)

Mohsen Aleenejad
Mohsen Aleenejad on 30 Jul 2020
The reason is that the topology is not physically able to follow the negative reference. The load consists of two parallel resistive branches. There is no power/energy generaor (at the right side of the converter) to constantly put back the energy into the 600V three phase system. As a rsult, the active power is always positive and Id cannot remain negative.

Communities

More Answers in the  Power Electronics Control

Categories

Find more on MATLAB in Help Center and File Exchange

Products


Release

R2019a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!