Simulink trying to map struct to run-time parameter
17 views (last 30 days)
Show older comments
Marshall Trout
on 21 Aug 2019
When attempting to run a function inside a Simulink model the simulation always fails due to the following error:
Unable to map parameter 'VarName' in 'FunctionName' to a run-time parameter. This parameter is an unsupported variable class such as a string, structure, cell, or an unsupported data type.
VarName is indeed a struct, but I do not understand why Simulink is attempting to make it a run-time parameter. VarName contains the initial conditions and online parameters used throughout the simulation. The Simulink model was built in 2013a and I am attempting to update it to run in 2017b. How can I prevent this error from occuring?
Thanks in advance.
0 Comments
Accepted Answer
Marshall Trout
on 26 Aug 2019
2 Comments
Toheed Ghandriz
on 26 Sep 2019
I got the same error but it was solved after removing the check mark in front of 'Tunable' in Edit data dialog box for 'VarName'. My VarName was structure too.
More Answers (1)
Noah Tang
on 28 Sep 2021
I was able to reproduce the same error message, and the comparison shows that the error happens when one field of my struct variable has an empty array as its value. Otherwise, the parameter passing process works just fine.
0 Comments