Simulink sample time with external sample clock?
Show older comments
Hi,
I want to run a S&H block with an external sample pulse. I am simulating a mixed signal digital PLL for a motor control. The phase detector is using boolean logic elements and is run from a 5Mhz pulse generator. The phase detector generates a phase count and a sample pulse about every 360Hz. I need this to drive a digital filter but am unclear how to use my boolean 360Hz sample pulse to act as the sample time for my z-domain digital filter.
Thanks ~

Accepted Answer
More Answers (0)
Categories
Find more on Signal Generation in Help Center and File Exchange
Products
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!