park transformation for single phase

19 views (last 30 days)
I am trying to transfer alpha abd beta with theta angle through park transformation ?
can anyone tell me what is the expected o/p form park transforation of the single phase conncected to grid ??
thanks

Accepted Answer

Arvind Sathyanarayanan
Arvind Sathyanarayanan on 22 Feb 2019
To transform single phase voltages/currents to shift your voltage/current by 90 degrees and use this value as β and your original signal as α. This can then be converted to dq0 using library blocks available in simulink.
It is difficult to say what the expected output is without knowing about your system but, generally d and q are dc values.

More Answers (1)

Arvind Sathyanarayanan
Arvind Sathyanarayanan on 25 Feb 2019
Can you please attach the model (*.slx) and other files required to run it? Also, which version of Matlab are you using?
  4 Comments
Arvind Sathyanarayanan
Arvind Sathyanarayanan on 28 Feb 2019
Saif,
You can phase shift using the complex phase shift block. I have never used this block as I don't have the toolbox.
The other option is to take the derivative of the sine signal. As you may know: and
Saif Zahran
Saif Zahran on 3 Mar 2019
i need to contact you please>