Probably in your Scope block, you have a parameter checked. Go to Settings->Logging and uncheck Limit data points to last parameter then rerun the simulation.
Why is there a blank zone at the start of my simulink simulation?
26 views (last 30 days)
Show older comments
I am quite new to Simulink and am trying a simple RL circuit to test it out. When I try to run the simulation for say 10 sec, in my scope (the output) the signal is blank (not zero just blank) for first 8 seconds and then there is the signal. If I change the total simulation time to say 5, the blank area is around 1 sec.
Is this inherent problem of Simulink, or am I doing something wrong?
NB: A colleague suggested that the blank time is the time Simulink is trying to solve the problem and after solving, it starts to show the results. I haven't seen any other simulation software that cannot give an output at time 0.0.
0 Comments
Accepted Answer
More Answers (0)
See Also
Categories
Find more on Sources in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!