Why does hilbert tranformer give a phase-shifted but amplitude-reduced signal?
6 views (last 30 days)
Show older comments
I have performed hilbert transform by using a FIR hilbert filter rather than the matlab built-in hilbert function. An example code is as follows:
fx = 10;
t = linspace(0,1,512);
x = 0.5*cos(2*pi*fx*t); %sampled signal
h = firpm(26,[0.1 0.8],[1 1],'h'); % hilbert filter
xh = conv(x,h,'same'); %hilbert transform of x
figure;
plot(t, [x;xh]); legend('Original','Transformed');
The resulting figure is given as follows:
How to address the problem to obtain the result equivalent to that by using hilbert function ?
0 Comments
Accepted Answer
Honglei Chen
on 13 Nov 2017
The phase shift is expected so I assume you are talking about the amplitude? This is because the filter is not ideal. If you do a
fvtool(h)
You can see that the magnitude response is not unity when the frequency is close to DC or Nyquest. In your case, the signal frequency is 10 and the sampling rate is 512, so that is close to DC so you see the attenuation. if you change your sampling rate to, say, 128, then the result would be similar to what you get from hilbert.
HTH
10 Comments
叶
on 12 Dec 2022
Do you have any idea to solve this problem?I mean if signal amplitude decreased,how can I get the normal ampliude?what should I do ?
More Answers (0)
See Also
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!