How to Trigger based on a incoming data value?

hello, I am aquiring a serial data from a sensor via xpc target. The sensor sends data in a continuous mode. I want to seperate the data byte from the packet of data. For that I want to trigger the data on the basis of a header byte say(0xC2).So that i can know where the packet starts. Can you suggest a way to do this

1 Comment

Is it certain that 0xC2 can never be part of the data stream, and can never occur as a checksum byte?

Sign in to comment.

 Accepted Answer

Please take a look at the white paper "xPC Target Serial Communication" available here http://www.mathworks.com/tagteam/68353_xPCTargetSerialCommunication.zip

More Answers (0)

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!