Error in port widths or dimensions. 'Input Port 1' of 'fccu/Zero-Order Hold' is a one dimensional vector with 1 elements.

2 views (last 30 days)
Error:Error in port widths or dimensions. 'Input Port 1' of 'fccu/Zero-Order Hold' is a one dimensional vector with 1 elements.

Answers (1)

Shantanu Dixit
Shantanu Dixit on 20 Aug 2024
Edited: Shantanu Dixit on 20 Aug 2024
Hi Hammed,
It is difficult to see the model clearly from the attached picture, but based on the two error messages (from Mux and zero-order-hold) it seems that the input dimensions to the Mux block are not what the model is expecting. In turn the output error from the mux block might be causing dimension error in Zero-Order-Hold block.
  • Review the input and dimensions of Mux and verify the configuration according to the number of input elements.
  • Ensure that the output from the Mux block matches this expected dimension.
  • Place Signal specification blocks at Mux to ensure expected functionality (by specifying attributes).

Categories

Find more on Event Functions in Help Center and File Exchange

Products


Release

R2024a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!