- Ensure the XSens device, RS232 to USB converter, and Speedgoat are correctly connected and powered.
- Check if your Speedgoat model supports USB devices and ensure the firmware/software is up to date.
- Use 'dmesg' and 'lsusb' commands to see if the device is detected at the hardware level.
- Review and adjust the Speedgoat configuration to enable and properly set up USB ports.
- Confirm compatibility of your MATLAB/Simulink versions with the Speedgoat and XSens device. Ensure the MATLAB support package for Speedgoat is installed.
- Test a direct serial connection if available, or try a different RS232 to USB converter.
Why does Speedgoat target not recognize usb device (xsens MTi-680G RS232 converter)?
1 view (last 30 days)
Show older comments
I want to read gnss data from my xsens MTi-680G using the RS232 converter connected in the Speedgoat usb port.
I have tried all the usb ports available on the Speedgoat but none of them seems working.
I have followed the guide: https://it.mathworks.com/matlabcentral/answers/2078751-why-is-my-usb-device-not-recognized-by-the-speedgoat-target-computer-with-an-error-saying-usb-seri but the
ls /dev
command doesn't show me any dev/serusbx device connected and so the Simulink model build fails with error:
Unable to load 'prova_gnss' on target computer 'TargetPC1': prova_gnss:INITIALIZE ERROR:USB serial port X error: No such file or directory (X number of usb device)
How could I overcome this problem ?
Thank you in advance
0 Comments
Answers (1)
Pratyush
on 20 Jun 2024
Hi Pietro,
To troubleshoot the issue of not being able to read GNSS data from an XSens MTi-680G via an RS232 converter connected to a Speedgoat USB port, follow these steps:
0 Comments
See Also
Categories
Find more on Target Computer Setup in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!