Cross Correlation and time lag
Show older comments
So in my project work, i placed two accelerometers on a single vibrating body and i want to find the timelag between the signals at either end...
[Correlation,lag]=xcorr(voltage1,voltage2);
corrlength=numel(Correlation);
[mag,Index] = max(abs(Correlation));
sampletime=0.003 ;%data acquisition
timelag=lag(Index)*(sampletime);
------------------------------------- voltage1 and voltage2 are bandpassed signals from the accelerometers in a specific noise range
But everytime i run the function, the timelag and lag amounts to zero, no matter how much i adjust the accelerometer sensitivity and position. Is it supposed to be zero? Or am i doing something wrong?
3 Comments
dpb
on 19 Apr 2015
" Or am i doing something wrong?"
Probably, but we can't tell. Possibly the resolution of the data acq at the sampling rate and with whatever filtering your using combined with the size and design of the structure is such that there is no discernible time lag between the two locations. 3 msec dt--> only 333 Hz which ain't much bandwidth--would have to be a very large structure it would seem.
Jade Sen
on 19 Apr 2015
dpb
on 20 Apr 2015
I'd start by looking at the two raw data signals with a scope triggered off the input first, then Accel A and see if the experimental setup is ok first...
Answers (0)
Categories
Find more on Audio I/O and Waveform Generation in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!