Tune “VariableName” of “From Workspace” block
6 views (last 30 days)
Show older comments
Enzo Yacometti
on 8 Feb 2024
Commented: Fangjun Jiang
on 9 Feb 2024
Hello, I’m building a realtime app with simulink (Simulink Realtime + App Designer) and I want to be able to tune the data loaded by a “From Workspace” block before running the model. The issue is the block parameter is non-tunable so I get the following warning: “Parameter ‘VariableName’ of ‘Model’ is non-tunable but refers to tunable variables”… I read here (https://it.mathworks.com/help/slrealtime/ug/tuning-block-parameters-and-model-parameters.html) that one can tune non-tunable block parameters defining Simulink objects, which is exactly what I’m doing but it’s not working. Can anyone help? Thank you.
0 Comments
Accepted Answer
Fangjun Jiang
on 8 Feb 2024
"Tune" usually means to change the value while the simulation is running, like a Gain value. What you need doesn't sound like "tune", but rather change the variable name before the simulation starts. To do that, you can use set_param('FromBlockPath','VariableName','MyVariable')
Or, you can change the value of the variable in the workspace, but not to change the variable name of the From Workspace block.
9 Comments
More Answers (0)