I simulated a simple AC circuit containg an AC Voltage Source and a Resistor from Simsacpe library, and using a Current Sensor and a Scope to show the current. The circuit model is as follows:

When I set the Stop Time to be 5 seconds, the result shown in Scope is right which is shown below:

However, when I set the Stop Time to be 10 seconds, the result shown in Scope is abnormal which is shown as follows:

How to solve this problem? Thanks very much!
3 Comments
Accepted Answer
Sabin
on 26 Jan 2023
This appears to be related to how the solver computes the step size. By explicitly setting the ‘Max step size’ in the Configuration Parameters (for example 0.1) would fix the issue.