Fmu with “canBeInst​antiatedOn​lyOncePerP​rocess” = false

12 views (last 30 days)
Claire
Claire on 19 Dec 2022
Edited: Yash on 23 Sep 2024
I would like to create an fmu from a simulink model where the “canBeInstantiatedOnlyOncePerProcess” fmu variable is set to false rather than true. Is there a way to set this?

Answers (1)

Yash
Yash on 23 Sep 2024
Edited: Yash on 23 Sep 2024
The canBeInstantiatedOnlyOncePerProcess flag in modelDescription.xml can be set to true or false for a Simulink model with fixed-step solver by either:
1) Using CLI: By setting the value of parameter SupportMultiInstance as on or off in the function exportToFMU (https://www.mathworks.com/help/slcompiler/ref/exporttofmu.html#mw_543093a5-7db7-4a99-82fa-2ab09dbc03c6) The flag is set to false when this parameter is specified as on.
2) From GUI: By selecting the check box "Support multiple instantiation per process" in the Advanced tab of Export Model to Standalone FMU
This functionality seems to have been supported since MATLAB R2024b by MathWorks and is compatible with FMI 2.0 and 3.0 standards.

Categories

Find more on RF Blockset Models for Transceivers in Help Center and File Exchange

Tags

Products


Release

R2022b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!