Nonconservation of energy when using system-level heat exchanger

3 views (last 30 days)
Hello, when I try the heat exchanger model, I find something weird.
For fluid 1 (left), G(h_in-h_out)=125249.28kJ/s, however, for fluid 2 (right), G(h_out-h_in)=21143.1kJ/s.
I can not figure out where the problem is. If anyone can help me, thank a lot.

Accepted Answer

Yifeng Tang
Yifeng Tang on 22 Dec 2022
I downloaded the model and noticed the flowrate on the right is very large. As you are still using the default port size (0.01m^2) for all the blocks, the local velocity can be very large (~50m/s), which means significant amount of enthalpy. For example, see line 315 of the source code of the reservoir block. Changing the port size to a much more reasonable value, say 0.5m^2, and you'll see the G*dh will again be (almost) conserved.

More Answers (0)

Categories

Find more on Two-Phase Fluid Library in Help Center and File Exchange

Products


Release

R2022b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!