Fuzzy controller warning solving
3 views (last 30 days)
Show older comments
I have designed a fuzzy logic controller (4 input 3 output) for the power split of an hybrid vehicle and I put it inside the HEV_SeriesParallel model from matlab. It runs and gives me possible results but I have many thousends of these warnings from the system: 'unable to use defuzzification method centroid on empty fuzzy set of output 1. Defuzzified output value set to its mean value'. Does it mean that the rules of my fuzzy don't cover some possible situation or something different? Thank you in advice.
0 Comments
Answers (1)
Sam Chak
on 16 Jul 2022
Basically, it implies that your fuzzy system is not designed properly. Yes, it can run, but the defuzzified output value is set to its mean value, which maybe the unintended output value in the first place.
If you can show the Rule Viewer, perhaps we can investigate the root cause.
In this example, no rules fired for the Outputs. That's why the defuzzified output values are set to its mean range values.

0 Comments
See Also
Categories
Find more on Fuzzy Logic in Simulink in Help Center and File Exchange
Community Treasure Hunt