The following two blocks cannot be connected in series
67 views (last 30 days)
Show older comments
arian hoseini
on 26 Jun 2022
Commented: arian hoseini
on 13 Nov 2022
i get this error and i tried to Add a high-value resistance in parallel with one of the two block but got another error
The following two blocks cannot be connected in series:
Block 1: 'Unonlinearelement_Variable Resistor/SrcI'
Block 2: 'Series RLC Branch2'
The first block, modeled as a current source, cannot be connected in series with the inductive element of the second block.
Add a high-value resistance in parallel with one of the two block.
You can also specify high-value resistive snubbers if the blocks have a snubber device.You can avoid the use of the snubber by selecting the 'Continuous' simulation type in the Solver tab of the Powergui and deselecting the 'Disable ideal switching' option in the Preferences tab of Powergui block.
0 Comments
Accepted Answer
Joel Van Sickel
on 28 Jun 2022
Hello Arian,
this is a limit based on how that block is implemented. You can either put a larger resistor in parallel with that block, or switch the solver to continuous, or you could make the circuit using simscape components instead of specialied technology, and then you won't have this limitation (the blue circuit blocks are simscape, the black ones are specialized power systems)
Regards,
Joel
More Answers (0)