Dynamically changing sample time for discrete time integrator

3 views (last 30 days)
Hello, I am programming a dynamic chemical process which has a changing contact time (which changes the dt in the dC/dt equation). I have used a discrete time integrator with a sample time set to the contact time and this works just as I want it to however as I want the flow rate through the process to be variable and this will change the sample time I need to set. *I want to be able to set the sample time to value calculated else where in the model that changes. Does anyone have any advice for things I could try or know that this is impossible so I can stop trying?
Any extra details needed I will provide happily.
  1 Comment
Roger
Roger on 20 Jun 2011
I have found a work around which is if the contact time is A then simply use a continous integrator with feed from equation that has dC/dt = A * x (where x is the original function). This gives me the desired answer I was looking for but I am a little wary of using this technique as I just made it up and am not sure of limitations / consequences. Any pearls of wisdom?

Sign in to comment.

Accepted Answer

Guy Rouleau
Guy Rouleau on 21 Jun 2011
Set the sample time of the discrete time integrator to be inherited and place it inside a triggered subsystem. You will need to make a logic to trigger the triggered subsystem at the right time.