Unexpected behavior with From Workspace block in Simulink
1 view (last 30 days)
Show older comments
The From Workspace block for Simulink is supposed to output data based on the time column in the variable. I have a model at a sample rate 5 times faster than the From Workspace, ie: 0.05 for Data, 0.001 for Model.
When I record the data from the From Workspace block at the Model sample rate of 0.001, I mostly see the data repeated 5 times but sometimes I see it repeated 6 times followed by 4 times for the next. This creates errors in my calculations because the expected data is wrong:
ie, 0 0 0 0 0 1 1 1 1 1 2 2 2 2 2 2 <- extra "2" 3 3 3 3 too little "3" 4 4 4 4 4
0 Comments
Accepted Answer
Kaustubha Govind
on 29 May 2013
(I presume you meant that 0.01 is your model's sample rate, because 0.05 is 50 times 0.001, not 5 times)
This looks like an floating-point/accuracy issue - 0.05*3 is slightly larger than 0.01*15:
>> format hex
>> 0.01*15
ans =
3fc3333333333333
>> 0.05*3
ans =
3fc3333333333334
Which is why, for the 15th sample, the previous data point (=2) is used.
Perhaps you can adjust the time column of the imported variable so that it is multiples of 0.01 instead of 0.05?
2 Comments
More Answers (0)
See Also
Categories
Find more on Event Functions in Help Center and File Exchange
Products
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!