Torque and Rotational motion sensor in simscape

68 views (last 30 days)
I have an issue in connecting an ideal torque sensor and an ideal rotational sensor to my BLDC motor.
I saw a lot of question and everybody says that the problem is put in parallel this two sensors. But i cannot fully understand the meaning.
Could you please answer with some photo about the differences?
I add a photo of my situation, honestly I cannot see a different way to use this two sensors together.
Thank you in advance
  1 Comment
Hyunuk Ha
Hyunuk Ha on 31 Dec 2020
Simscape is multi-domain plant modeling tool, and each domain has its own variables, which defines power.
In the mechanical rotational domain, two variables are angular velocity and torque.
So, you can detect angular velocity or torque from that domain.
You can refer to the detailed info. at :

Sign in to comment.

Answers (1)

Juan Sagarduy
Juan Sagarduy on 4 Jan 2021
Hi Leonardo
Torque is a through variable measured with a torque sensor (TS) in series with the shaft of the motor. Speed is an across variable (potential) measured with a rotational sensor (Rot S) in parallel.
In your case, if S is the shaft of the motor, the connection is S - (TS - port R) - (TS - port C) - (Rot S - port R) - mechanical load (inertia, torque source...) (Rot S - port C) connected to a mechanical reference is correct.
Hope this helps out Regards Juan
  3 Comments
彬 魏
彬 魏 on 21 Sep 2021
The issue was due to the torque sensor being connected incorrectly. In the rotational domain, angular velocity is the across variable and torque is the through variable. The velocity sensor measures the change in velocity across R and C without any torque going through the sensor. On the other hand, the torque sensor measures the torque going through the sensor without any change in velocity across R and C. In the not working model, the torque sensor connection means that the velocity at the junction is the same as the mechanical reference, which is zero velocity. That is why the results are wrong.
If the intent is to measure net torque on the hydraulic machine, then the torque sensor should be connected between the machine and the junction point (like how you would connect a hydraulic flow rate sensor).
This was the cause for a* very specific* model. If you cannot resolve your issue by going through the Simscape documentation and you have a valid license with maintenance, then please contact Technical Support.