When is the 'ModelRefe​renceVersi​onMismatch​Message' Simulink model parameter editable?

3 views (last 30 days)
When I open a model's test harness, I receive the following error:
I would like to disable the "ModelReferenceVersionMismatchMessage" parameter, but when I go to the configuration parameters, it's greyed-out and I can't modify it. When I try to edit it from the command line, I also receive errors:
The documentation page for this parameter doesn't give any hints as to when it is possible to actually edit it. How can I edit it?

Accepted Answer

Fangjun Jiang
Fangjun Jiang on 9 Apr 2020
Try this
model='sldemo_mdlref_basic';
open_system(model);
get_param(model,'ModelReferenceVersionMismatchMessage')
set_param(model,'ModelReferenceVersionMismatchMessage','warning')
set_param(model,'ModelReferenceVersionMismatchMessage','none')
  3 Comments
Monika Jaskolka
Monika Jaskolka on 20 Apr 2020
Thank you. You're right. I can enable the parameter by modifying the custom .tlc file like this:
slConfigUISetEnabled(hDlg, hSrc, 'ModelReferenceVersionMismatchMessage', 'true');

Sign in to comment.

More Answers (0)

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!