Simulink MPC Designer ZOH FOH Error
9 views (last 30 days)
Show older comments
I am trying to design an MPC controller using the simulink controller toolbox. Whenever I try to make the MPC sample time less that 1, I get the following error: "The "zoh" and "foh" methods cannot be used for discrete models with poles near z=0" Could someone please explain what the error means and how I fit my controller? Thanks
2 Comments
Jordan Olson
on 1 Jul 2020
I'm also having this issue, but changing the sample time in the MPC doesn't fix it.
Answers (1)
dekun wang
on 18 May 2021
poles in discrete domain near z=0 means poles in continuous domain tending to -infinite which means your system's natural frequency is infinitely large. It cannot be true for any systems. So my suggestion would be to double check your plant model.