How to get unity power factor in three phase rectifier by hysteresis current controller
Show older comments
attain unity power factor in input side by hysteresis current controller
Answers (5)
Anees Ansari
on 20 Jun 2015
0 votes
Purushottama Rao
on 20 Jun 2015
0 votes
Steps: 1) Sample the input line voltage signal. Use a PLL for syncronization, the output of which is a unit mag sinusoidal signal inphase with the line voltage. 2) Prepare the ref current. This can be obtained by multiplying the required curret rms value with the PLL output. 3) Measure the input current 4) Calculate the error between the above two currents 5) Define a hystresis controller with the defined hystersis level. Relay block in simulink does this for you. Hystersis limits defines the switching frequency and THD. 6) Pass the output from hystersis to the switches directly.
It should give you the required output. ALL THE VERY BEST
4 Comments
Anees Ansari
on 20 Jun 2015
Purushottama Rao
on 22 Jun 2015
I propose to have your model or a print screen of it to fix it.
Anees Ansari
on 24 Jun 2015
Anees Ansari
on 24 Jun 2015
Anees Ansari
on 24 Jun 2015
0 votes
Anees Ansari
on 24 Jun 2015
0 votes
3 Comments
Purushottama Rao
on 25 Jun 2015
Edited: Purushottama Rao
on 25 Jun 2015
Dear Anees, Thanks for the info. Picture was not clear especially the lower power part Below the diode bridge.I would like to see what is there inside it?
I could not find any return path other than the diode bridge for the phase current. Gv more details. Share your model for better help
Anees Ansari
on 14 Jul 2015
Anees Ansari
on 14 Jul 2015
Anees Ansari
on 14 Jul 2015
0 votes
Categories
Find more on Specialized Power Systems in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!