- Open-Circuit Voltage for Zero Sequence: you'll need to perform a simulation or measurement under zero sequence conditions. You can apply a zero sequence voltage at the motor terminals while keeping the other phases open-circuited. Measure the resulting voltage across the motor terminals.
- Short-Circuit Current for Zero Sequence: Similarly, you'll need to simulate or measure the short-circuit current under zero sequence conditions. This involves applying a short circuit to the motor terminals while injecting a zero sequence current. Measure the resulting current.
how to calculate Zero Sequence inductance(L0)For IPMSM delta connection
13 views (last 30 days)
Show older comments
I have Ld,Lq values for IPMSM delta connection.These Ld,Lq values were taken from motor cad.But Motor cad could not provided Zero Sequence inductance(L0).So,I want to know how to calculate Zero sequence inductance(L0) for ipmsm delta connection.
0 Comments
Accepted Answer
Mohamad Nazir
on 28 Aug 2023
The zero sequence inductance can be calculated using L0 = V0open/I0short where V0open is the open-circuit voltage for the zero sequence and I0short is the short-circuit current for the zero sequence.
Hope this helps
0 Comments
More Answers (0)
Communities
More Answers in the Power Electronics Control
See Also
Categories
Find more on Simscape Electrical in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!