readasync
(To be removed) Read data asynchronously from device
This serial
object function will be removed in a future release. Use
serialport
object functions instead. For more information on updating your code, see Version History.
Syntax
readasync(obj)
readasync(obj,size)
Description
readasync(obj)
initiates an asynchronous
read operation on the serial port object, obj
.
readasync(obj,size)
asynchronously reads,
at most, the number of bytes given by size
. If
size
is greater than the difference between the
InputBufferSize
property value and the
BytesAvailable
property value, an error is returned.
Examples
This example creates the serial port object s
on a Windows® platform. It connects s
to a Tektronix® TDS 210 oscilloscope, configures s
to read data
asynchronously only if readasync
is issued, and configures the
instrument to return the peak-to-peak value of the signal on channel 1.
s = serial('COM1'); fopen(s) s.ReadAsyncMode = 'manual'; fprintf(s,'Measurement:Meas1:Source CH1') fprintf(s,'Measurement:Meas1:Type Pk2Pk') fprintf(s,'Measurement:Meas1:Value?')
Begin reading data asynchronously from the instrument using
readasync
. When the read operation is complete, return the
data to the MATLAB® workspace using fscanf
.
readasync(s) s.BytesAvailable
ans = 15
out = fscanf(s)
out = 2.0399999619E0
fclose(s)
Tips
Before you can read data, you must connect obj
to the device with
the fopen
function. A connected serial port object has a
Status
property value of open
. An error
is returned if you attempt to perform a read operation while obj
is not connected to the device.
Only use readasync
to configure the
ReadAsyncMode
property to manual
.
readasync
is ignored if used when
ReadAsyncMode
is continuous
.
The TransferStatus
property indicates if an asynchronous read
or write operation is in progress. You can write data while an asynchronous read is
in progress because serial ports have separate read and write pins. You can stop
asynchronous read and write operations with the stopasync
function.
You can monitor the amount of data stored in the input buffer with the
BytesAvailable
property. Additionally, you can use the
BytesAvailableFcn
property to execute a callback function
when the terminator or the specified amount of data is read.
Rules for Completing an Asynchronous Read Operation
An asynchronous read operation with readasync
completes
when one of these conditions is met:
The terminator specified by the
Terminator
property is read.The time specified by the
Timeout
property passes.The specified number of bytes is read.
The input buffer is filled (if
size
is not specified).
Because readasync
checks for the terminator, this function
can be slow. To increase speed, you might want to configure
ReadAsyncMode
to continuous
and
continuously return data to the input buffer as soon as it is available from the
device.