Query Instrument

(To be removed) Query or read instrument data

Query Instrument will be removed in a future release. Use the interface-specific blocks instead. For more information on updating your code, see Version History.

Library

Instrument Control Toolbox

  • Query Instrument block

Description

The Query Instrument block configures and opens an interface to an instrument, initializes the instrument, and queries the instrument for data. The configuration and initialization happen at the start of the model execution. The block queries the instrument for data during model run time.

The block has no input ports. The block has one output port corresponding to the data received from the instrument.

Other Supported Features

  • This block supports the use of accelerator mode, but not Rapid Accelerator or code generation.

  • The block supports the use of model referencing, so that your model can include other Simulink® models as modular components.

For more information on these features, see the Simulink documentation.

Parameters

Block sample time

The Block sample time parameter is the only setting outside of the dialog box tabs. The default value is 1. Setting the value to -1 sets the block to inherit timing. A positive value is used as the sample period.

Hardware Configuration Tab

The Hardware Configuration tab is where you define the settings for communications with your instrument. You have two choices about establishing an interface:

  • Specify a new hardware configuration.

  • Use an interface object from the MATLAB® workspace.

The following figure shows the Hardware Configuration tab set to specify a new hardware configuration using a serial port interface.

Because some parameters apply to multiple interface types, they appear here in alphabetical order.

Baudrate

The rate at which bits are transmitted for the serial or VISA serial interface.

Board index

The index of the board used for GPIB, VISA GPIB, VISA TCPIP, or VISA USB interface to the instrument.

Board vendor

The vendor of the GPIB board used for the interface to the instrument. Your choices are Keysight® (formerly Agilent®), ICS Electronics™, Measurement Computing™ (MCC), and National Instruments™.

Chassis index

The index number of the VXI chassis. Used for VISA VXI and VISA VXI-GPIB interface types.

Buffer size

The total number of bytes that can be stored in the software input buffer during a read operation.

Interface

Select the type of hardware interface to the instrument. Your options are those interfaces supported by the Instrument Control Toolbox™ software. The previous figure shows a configuration for a serial port interface.

Logical address

The logical address of the VXI instrument. Used for VISA VXI and VISA VXI-GPIB interface types.

Manufacturer ID

The manufacturer ID of the VISA USB instrument. See ManufacturerID property for more information.

Model code

The model code of the VISA USB instrument. See ModelCode property for more information.

Port

The port for the serial interface: COM1, COM2, etc.

Primary address

The primary address of the instrument on the GPIB.

Remote host

The host name or IP address of the instrument. Used for UDP, TCPIP, or VISA TCPIP interface types.

Remote port

The port on the instrument or remote host used for communication. Used for UDP, TCPIP, or VISA TCPIP interface types.

Secondary address

The secondary address of the instrument on the GPIB.

Serial number

The serial number of the VISA USB instrument defined as a character vector. See SerialNumber property for more information.

Timeout

Time in seconds allowed to complete the query operation.

VISA vendor

The vendor of the VISA used for any of the VISA interface types. Your choices are Keysight (formerly Agilent), National Instruments, and Tektronix®.

Use interface object from MATLAB workspace

Select this option to use an interface object from the MATLAB workspace.

Workspace object

Enter the object name that you want to use from the MATLAB workspace.

Instrument Initialization Tab

The Instrument Initialization tab is where you define what happens when you first open your connection to the instrument.

None

The default initialization option is none.

Send string

A string sent to the instrument as an instrument command to initialize the instrument or set it up in a known state.

Execute function

Any function that has as its only argument the interface object representing the instrument. You can write this function to include several instrument commands and initialization data.

Query Tab

The Query tab is where you define the optional query command, set the format for the response, and define what the block does after the initial instrument response.

Query command

This is the query command that is sent to the instrument. It is usually a request for instrument status or data. This command is optional — if you are retrieving information or data from the instrument and no query command is necessary to do that, you can leave this field blank.

Data format

Your options are ASCII, Binary, or Binblock (binary block — the binblock format is described in the binblockwrite function reference page).

ASCII format string

Available only when the format is ASCII, this defines the format string for the data. For a list of formats, see the fscanf function.

Precision

Used for binary or binblock format. Your options are:

  • 8-bit integer (default)

  • 16-bit integer

  • 32-bit integer

  • 8-bit unsigned integer

  • 16-bit unsigned integer

  • 32-bit unsigned integer

  • 32-bit float

  • 64-bit float

Byte order

When using binary or binblock format with more than 8 bits, you can specify the instrument's byte order for the data. Your options are Big Endian or Little Endian.

Binary values to read

Used for binary format. Specify the number of binary values to read from the instrument.

Remove additional bytes from input buffer

Select this option if you want to remove any additional bytes from the input buffer before querying.

After initial response

This defines the action to take after the first response from the instrument. Your options are Repeat query for new data, Recycle original data, Hold final value, Output zero, or Stop simulation.

Enable frame output

A frame is a sequence of samples combined into a single vector. In frame-based processing all the samples in a frame are processed simultaneously. In sample-based processing, samples are processed one at a time. The advantage of frame-based processing is that it can greatly increase the speed of a simulation. For example, you might use frames if you are reading a waveform from your instrument rather than a single-point measurement.

Frame size

Frame size determines the number of samples in a frame.

Note

Hardware information shown in the dialog box is determined and cached when you first open the dialog box. To refresh the display with new values, restart MATLAB.

Version History

Introduced before R2006a

expand all

R2024b: Errors

This block throws an error when added to a model. Opening any existing model with this block causes an error. The model cannot be simulated because of this error. You can still open the block parameter dialog and see the parameter values.

Use the interface-specific blocks instead:

These interface-specific blocks all support additional properties and have improved performance compared to Query Instrument and To Instrument.