Simulink data type conversion, single to uint16.
67 views (last 30 days)
Show older comments
Hello,
I'm using simulink and I need to convert from a single to a uint16.
Could a kind soul kindly explain why the output of a single (with range 0-2pi) equates to an uint16 of zero?
Here is an example:
And here is the output of that example:
There are a number of uint16 signals in my model with range 0-4000 (I am reading from sevreral ADC). All behave as expected. Just this conversion, in this instance.
5 Comments
Accepted Answer
Hitesh
on 19 Sep 2024 at 9:27
Edited: Hitesh
on 19 Sep 2024 at 9:28
Hi Jamie,
I am assuming that you have used "Data Type Conversion" block, and the conversion to "uint16" resulted in unexpected values due to the default integer rounding mode being set to "floor" in Block Parameters. If you change the rounding mode to "round," you will achieve the expected results when converting from "single" to "uint16".
More Answers (0)
See Also
Categories
Find more on Sources in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!