Eight-Pulse Gate Multiplexer
Libraries:
Simscape /
Electrical /
Semiconductors & Converters /
Converters
Description
The Eight-Pulse Gate Multiplexer block routes gate voltage signals to the eight switching devices in a Bidirectional DC-DC Converter block. The block multiplexes the eight separate gate signals into a single vector.
When you set the Gate-control port parameter to
Electrical
, the block exposes conserving ports that
represent electrical reference points. These ports are associated with the individual
phase voltages that connect to the high-side switching devices and the negative DC
voltage common to each low-side switching device in the Bidirectional DC-DC
Converter block.
Ports
Input
G1 — Gate-control voltage signal 1, V
physical signal
Physical signal port associated with the gate terminal of the first switching device in a Bidirectional DC-DC Converter block.
Dependencies
To enable this port, set Gate-control port to
PS
.
Data Types: double
G2 — Gate-control voltage signal 2, V
physical signal
Physical signal port associated with the gate terminal of the second switching device in a Bidirectional DC-DC Converter block.
Dependencies
To enable this port, set Gate-control port to
PS
.
Data Types: double
G3 — Gate-control voltage signal 3, V
physical signal
Physical signal port associated with the gate terminal of the third switching device in a Bidirectional DC-DC Converter block.
Dependencies
To enable this port, set Gate-control port to
PS
.
Data Types: double
G4 — Gate-control voltage signal 4, V
physical signal
Physical signal port associated with the gate terminal of the fourth switching device in a Bidirectional DC-DC Converter block.
Dependencies
To enable this port, set Gate-control port to
PS
.
Data Types: double
G5 — Gate-control voltage signal 5, V
physical signal
Physical signal port associated with the gate terminal of the fifth switching device in a Bidirectional DC-DC Converter block.
Dependencies
To enable this port, set Gate-control port to
PS
.
Data Types: double
G6 — Gate-control voltage signal 6, V
physical signal
Physical signal port associated with the gate terminal of the sixth switching device in a Bidirectional DC-DC Converter block.
Dependencies
To enable this port, set Gate-control port to
PS
.
Data Types: double
G7 — Gate-control voltage signal 7, V
physical signal
Physical signal port associated with the gate terminal of the seventh switching device in a Bidirectional DC-DC Converter block.
Dependencies
To enable this port, set Gate-control port to
PS
.
Data Types: double
G8 — Gate-control voltage signal 8, V
physical signal
Physical signal port associated with the gate terminal of the eighth switching device in a Bidirectional DC-DC Converter block.
Dependencies
To enable this port, set Gate-control port to
PS
.
Data Types: double
Conserving
G1 — Gate-control voltage signal 1
electrical
Electrical conserving port associated with the gate terminal of the first switching device in a Bidirectional DC-DC Converter block.
Dependencies
To enable this port, set Gate-control port to
Electrical
.
a — A-phase reference point
electrical
Electrical conserving port associated with the A-phase for the high-side switching device.
Dependencies
To enable this port, set Gate-control port to
Electrical
.
G3 — Gate-control voltage signal 3
electrical
Electrical conserving port associated with the gate terminal of the third switching device in a Bidirectional DC-DC Converter block.
Dependencies
To enable this port, set Gate-control port to
Electrical
.
b — B-phase reference point
electrical
Electrical conserving port associated with the B-phase for the high-side switching device.
Dependencies
To enable this port, set Gate-control port to
Electrical
.
G5 — Gate-control voltage signal 5
electrical
Electrical conserving port associated with the gate terminal of the fifth switching device in a Bidirectional DC-DC Converter block.
Dependencies
To enable this port, set Gate-control port to
Electrical
.
c — C-phase reference point
electrical
Electrical conserving port associated with the C-phase for the high-side switching device.
Dependencies
To enable this port, set Gate-control port to
Electrical
.
G7 — Gate-control voltage signal 7
electrical
Electrical conserving port associated with the gate terminal of the seventh switching device in a Bidirectional DC-DC Converter block.
Dependencies
To enable this port, set Gate-control port to
Electrical
.
d — D-phase reference point
electrical
Electrical conserving port associated with the D-phase for the high-side switching device.
Dependencies
To enable this port, set Gate-control port to
Electrical
.
G2 — Gate-control voltage signal 2
electrical
Electrical conserving port associated with the gate terminal of the second switching device in a Bidirectional DC-DC Converter block.
Dependencies
To enable this port, set Gate-control port to
Electrical
.
G4 — Gate-control voltage signal 4
electrical
Electrical conserving port associated with the gate terminal of the fourth switching device in a Bidirectional DC-DC Converter block.
Dependencies
To enable this port, set Gate-control port to
Electrical
.
G6 — Gate-control voltage signal 6
electrical
Electrical conserving port associated with the gate terminal of the sixth switching device in a Bidirectional DC-DC Converter block.
Dependencies
To enable this port, set Gate-control port to
Electrical
.
G8 — Gate-control voltage signal 8
electrical
Electrical conserving port associated with the gate terminal of the eighth switching device in a Bidirectional DC-DC Converter block.
Dependencies
To enable this port, set Gate-control port to
Electrical
.
L — DC reference point
electrical
Electrical conserving port associated with the DC negative connection for the low-side switching device.
Dependencies
To enable this port, set Gate-control port to
Electrical
.
Parameters
Gate-control port — Gate control port
PS
(default) | Electrical
Whether to expose physical signal or electrical control ports.
Extended Capabilities
C/C++ Code Generation
Generate C and C++ code using Simulink® Coder™.
Version History
Introduced in R2022a
MATLAB Command
You clicked a link that corresponds to this MATLAB command:
Run the command by entering it in the MATLAB Command Window. Web browsers do not support MATLAB commands.
Select a Web Site
Choose a web site to get translated content where available and see local events and offers. Based on your location, we recommend that you select: .
You can also select a web site from the following list:
How to Get Best Site Performance
Select the China site (in Chinese or English) for best site performance. Other MathWorks country sites are not optimized for visits from your location.
Americas
- América Latina (Español)
- Canada (English)
- United States (English)
Europe
- Belgium (English)
- Denmark (English)
- Deutschland (Deutsch)
- España (Español)
- Finland (English)
- France (Français)
- Ireland (English)
- Italia (Italiano)
- Luxembourg (English)
- Netherlands (English)
- Norway (English)
- Österreich (Deutsch)
- Portugal (English)
- Sweden (English)
- Switzerland
- United Kingdom (English)