Controlled Voltage Source
Implement controlled voltage source
Libraries:
Simscape /
Electrical /
Specialized Power Systems /
Sources
Description
The Controlled Voltage Source block converts a Simulink® input signal into an equivalent voltage source. The generated voltage is driven by the input signal of the block.
You can initialize the Controlled Voltage Source block with a specific AC or DC voltage. If you want to start the simulation in steady state, the Simulink input must be connected to a signal that begins the simulation as a sinusoidal or DC waveform that corresponds to the initial values.
Note
The Simulink input signal must be a complex value (phasor) when you use the Controlled Voltage Source block in a phasor simulation, because the Simscape™ Electrical™ Specialized Power Systems software does not automatically convert input signals from time-domain signals to complex (phasor) signals.
Examples
Ports
Input
Conserving
Parameters
Extended Capabilities
Version History
Introduced before R2006a