Reluctance
R2026bMagnetic reluctance
Libraries:
Simscape /
Foundation Library /
Magnetic /
Magnetic Elements
Description
The Reluctance block models a magnetic reluctance, that is, a component that resists flux flow. The ratio of the magnetomotive force (mmf) across the component to the resulting flux that flows through the component is constant, and the ratio value is defined as the reluctance. Reluctance depends on the geometry of the section being modeled.
The block uses the equations
where:
MMF is the magnetomotive force (mmf) across the component.
Φ is the flux through the component.
is the reluctance.
g is the thickness of the section being modeled, or the length of air gap.
μ0 is the permeability constant.
μr is the relative permeability of the material.
A is the cross-sectional area of the section being modeled.
Connections N and S are magnetic conserving ports. The mmf across the reluctance is , and the sign of the flux is positive when it flows through the device from N to S.
Variables
To set the priority and initial target values for the block variables prior to simulation, use the Initial Targets section in the block dialog box or Property Inspector. For more information, see Set Priority and Initial Target for Block Variables.
Nominal values provide a way to specify the expected magnitude of a variable in a model. Using system scaling based on nominal values increases the simulation robustness. Nominal values can come from different sources, one of which is the Nominal Values section in the block dialog box or Property Inspector. For more information, see Modify Nominal Values for a Block Variable.
Examples
Ports
Conserving
Parameters
Extended Capabilities
Version History
Introduced in R2010a