STM32CubeMX Configuration for Voltage Mode Control

Click Launch in Configuration Parameters to open the selected STM32CubeMX project in STM32CubeMX tool.

Launch STM32CubeMX

Open STM32CubeMX project and perform the following configurations.

STM32CubeMX Project Manager Configuration

Select the preferred toolchain.

STM32CubeMX configuration

STM32CubeMX Clock Configuration

  • The ADC12 clock is set to 56.66 MHz.

  • HRTIM & USART3 clocks are set to 170 MHz.

Clock configuration

STM32CubeMX Pin Configuration

ADC Mode Settings

ADC Channel 4 (ADC_IN4) has the user label BUCKBOOST_VOUT and is connected to PA3. This is the output voltage of the buck converter that is regulated.

ADC configuration

ADC Parameter Settings

  • Data Alignment is set to Right alignment. This stores the 12-bit result from the ADC in the 16-bit results register with the right alignment. That means the Lower12-bits (plus 1 sign bit) of the 16-bit register is used.

  • Under the ADC_Regular_ConversionMode section, set the External Trigger Conversion Source to High-Resolution Trigger 1 event. Later set the External Trigger Conversion Edge to Trigger detection on the rising edge.

  • For the voltage mode buck converter, only one ADC conversion is required. This is the output voltage rail that is regulated. Therefore, the number of conversions is currently set to 1. The ADC conversion is configured by expanding the Rank subcategory.

  • Set the Channel to Channel 4.

STM32CubeMX ADC

HRTIM Mode Settings

The High resolution timer module is configured to generate the PWM. The Buck power stage is driven by Timer C.

HRTIM configuration

HRTIM Parameter Settings

  • Set the Period value to 27200 with the resulting PWM period now calculated as 200000 Hz.

  • Set Dead Time insertion to Deadtime is inserted between output 1 and output 2. This enables the deadtime section which allows the outputs to be configured such that both high-side and low-side switches are never driven at the same time.HRTIM - period

  • For Compare Unit 1 section change the configuration setting to Enable. Enter a Compare Value of 0. This is the initial value of the duty cycle fixed to 0 %.

  • For Compare Unit 3 section change the configuration setting to Enable. Enter a Compare Value of 50. This is the event that is used to trigger the ADC sample. This can be moved to a clean point in the switching cycle, which means away from the turn-on or turn-off of the switch.

    HRTIM enable compare unit

  • Set Rising Value to 75 and Falling Value to 300.

  • The dead-time ticks fDTG are generated from fHRTIM and a prescaler:

    • fDTG = fHRTIM * 8, and 
      because fHRTIM = 170 MHz: fDTG = 170 MHz * 8 = 1360 MHz

    • therefore:

      1 dead-time tick = 0.735 ns

    • Hence:

      Rising value = 75 ticks = 55 ns Falling value = 300 ticks = 220 ns

    HRTIM

  • Under the Output 1 Configuration section, change the Set Source Selection number to 1. Change the 1st Set Source event to Timer period event forces the output to its active state.

  • Change the Reset Source Selection number to 1. Change the 1st Reset Source event to Timer compare 1 event forces the output to its inactive state.

  • Finally, set the Fault Level to Output at the inactive level when in FAULT state.

  • The Output 2 Configuration section is left unchanged as this output is driven by the dead-time.

    HR Timer

  • Enable the ADC Trigger 1 and set the Update Trigger Source to Timer C, enter the number of Trigger Sources Selection to 1. From the 1st Trigger Source drop-down, select ADC Trigger on Timer C compare 3.

  • This is the event that triggers the ADC.

    ADC trigger

USART3 mode and configuration settings

Configure the USART3 for Host-Target communication.

USART

GPIO configuration settings

  • BUCKBOOST P2 DRIVE and BUCKBOOST N2 DRIVE are not used in the Buck-only configuration.

  • However, the BUCKBOOST P2 DRIVE must be High to support the Buck-only configuration.

  • BUCKBOOST USBPD EN would enable the input 5V to the power converter stage.

    GPIO configuration