Main Content

coder.asap2.Characteristic

Create characteristic object

Since R2022b

Description

Create a characteristic object to define parameter element and export it to an ASAP2 file.

Creation

param = coder.asap2.Characteristic creates a characteristic object. You can use the object to define a characteristic element and export it to an ASAP2 file.

Properties

expand all

Specify a name for the custom parameter.

Example: "CustomParameter_1"

Specify comments and description of the parameter.

Example: "Description of the parameter"

Specify the list of parameters referred in the group which are already present in the description object.

Example: MAP

Specify the address of the custom parameter.

Example: 0x1234

Specify a name for the conversion method of the custom parameter.

Example: custom_conversionmethod

Specify the minimum possible value for the custom parameter.

Example: 0

Specify the maximum possible value for the custom parameter.

Example: 63365

Specify symbols for address replacement.

Example: "/* @ECU_Address@CHARACTERISTIC_1@ */"

Specify additional address information.

Example: 1

Specify the calibration access type for the custom parameter.

Example: ReadOnly

Specify a display name for the parameter to appear on calibration tool.

Example: CustomParam_1

Specify a display format for the parameter to appear on calibration tool.

Example: %3.4

Specify to handle the single bits.

Example: 0x3a

Specify the parameters for the axis description.

Example: Custom_Axis

Specify true to export array as a look up table of type FIX_AXIS.

Example: true

Set true to transpose the axis. It is applicable only for lookup tables

Example: true

Specify a valid measurement name as a reference in the ASAP2 file. It is applicable only for lookup tables.

Example: Custom_Measurement

Name of the record layout.

Example: "Record_DATATYPE"

Specify the dimensions for an array data type.

Example: 2

Specify true to describe standard axis as com axis.

Example: true

Specify true to export the parameter and false to not export the parameter to ASAP2 file.

Example: false

Specify reference to symbol name within a linker map file.

Example: struct('SymbolName','p1_SymbolName','Offset',1)

Specify the maximum refresh rate.

Example: struct('ScalingUnit',ScalingUnits.ONE_MILLI_SEC,'Rate',100)

Specify any additional description that needs to be populated in the characteristic.

Example: "additional information"

Examples

collapse all

Add, update, filter, find, and remove ECU descriptions in an ASAP2 file.

Open and Build Example Model

Open the example model ASAP2Demo

open_system("ASAP2Demo");

Build the model.

slbuild("ASAP2Demo");
### Searching for referenced models in model 'ASAP2Demo'.
### Found 1 model reference targets to update.
### Starting serial model reference code generation build.
### Successfully updated the model reference code generation target for: ASAP2DemoModelRef
### Starting build procedure for: ASAP2Demo
### Successful completion of build procedure for: ASAP2Demo

Build Summary

Model reference code generation targets:

Model              Build Reason                                 Status                        Build Duration
============================================================================================================
ASAP2DemoModelRef  Target (ASAP2DemoModelRef.c) did not exist.  Code generated and compiled.  0h 0m 28.438s 

Top model targets:

Model      Build Reason                                         Status                        Build Duration
============================================================================================================
ASAP2Demo  Information cache folder or artifacts were missing.  Code generated and compiled.  0h 0m 43.931s 

2 of 2 models built (0 models already up to date)
Build duration: 0h 1m 15.078s

Create the ECU description object for the model.

descObj = coder.asap2.getEcuDescriptions("ASAP2Demo");

Get the list of available computation methods in the description object.

find(descObj,"CompuMethod")
ans = 1x10 string
    "ASAP2DemoModelRef_CM_double"    "ASAP2DemoModelRef_CM_int16_rpm"    "ASAP2Demo_CM_double"    "ASAP2Demo_CM_double_m_per__s_2_"    "ASAP2Demo_CM_double_rpm"    "ASAP2Demo_CM_int32"    "ASAP2Demo_CM_single"    "ASAP2Demo_CM_single_m_per__s_2_"    "ASAP2Demo_CM_single_rpm"    "ASAP2Demo_CM_uint8"

Filter the computation methods and get a list of computation methods that use rpm as the unit.

find(descObj,"CompuMethod",Units='rpm')
ans = 1x3 string
    "ASAP2DemoModelRef_CM_int16_rpm"    "ASAP2Demo_CM_double_rpm"    "ASAP2Demo_CM_single_rpm"

Create and Add Custom Computation Method

To add a new computation method to the ASAP2 file, create a custom computation method.

CompuMethod_1 = coder.asap2.CompuMethod;
CompuMethod_1.Name = 'CompuMethod_1';
CompuMethod_1.ConversionType = 'LINEAR';
CompuMethod_1.Coefficients = [2 3];
CompuMethod_1.LongIdentifier = 'longIdentifierTest';
CompuMethod_1.Format = '%2.3';
CompuMethod_1.Units = 's';

Add the custom computation method to the ECU description object.

add(descObj,CompuMethod_1);

Get the properties of the newly added computation method.

get(descObj,"CompuMethod","CompuMethod_1")
ans = 
  CompuMethod with properties:

               Name: 'CompuMethod_1'
     LongIdentifier: 'longIdentifierTest'
             Format: '%2.3'
              Units: 's'
       Coefficients: [2 3]
     ConversionType: 'LINEAR'
    CompuVTabValues: [1x1 struct]
         CustomData: ""

To modify a property of the computation method, use set function. Update the ConversionType field of the computation method to TAB_VERB and define the CompuVTabValues.

set(descObj,"CompuMethod","CompuMethod_1",ConversionType="TAB_VERB");
set(descObj,"CompuMethod","CompuMethod_1",CompuVTabValues = struct('Literals',["false" "true"],'Values',[0 1]));

Get the properties to see the modified fields.

modifiedprop = get(descObj,"CompuMethod","CompuMethod_1")
modifiedprop = 
  CompuMethod with properties:

               Name: 'CompuMethod_1'
     LongIdentifier: 'longIdentifierTest'
             Format: '%2.3'
              Units: 's'
       Coefficients: [2 3]
     ConversionType: "TAB_VERB"
    CompuVTabValues: [1x1 struct]
         CustomData: ""

modifiedprop.CompuVTabValues
ans = struct with fields:
    Literals: ["false"    "true"]
      Values: [0 1]

Generate the ASAP2 file using the updated ECU description object and verify that the ASAP2 file contains the computation method CompuMethod_1.

coder.asap2.export("ASAP2Demo",CustomEcuDescriptions=descObj);
Following Characteristics or Measurements with unsupported data types are not exported in ASAP2 file. "ASAP2Demo_DW.ASAP2DemoModelRef_InstanceData"

Delete Computation Method

Remove the newly added computation method from the description object.

delete(descObj,"CompuMethod","CompuMethod_1");

Create and Add Custom Characteristic

To add a new characteristic to the ASAP2 file, create a custom characteristic.

Parameter_1 = coder.asap2.Characteristic;
Parameter_1.Name = 'Custom_parameter1';
Parameter_1.LongIdentifier = 'longIdentifierParam';
Parameter_1.UpperLimit = 255;
Parameter_1.LowerLimit = 0;

Add the custom characteristic to the ECU description object.

add(descObj,Parameter_1);

Get the properties of the newly added characteristic.

get(descObj,"Characteristic","Custom_parameter1")
ans = 
  Characteristic with properties:

                   Name: 'Custom_parameter1'
         LongIdentifier: 'longIdentifierParam'
                   Type: 'VALUE'
             EcuAddress: '0x0000'
        CompuMethodName: 'NO_COMPU_METHOD'
             LowerLimit: 0
             UpperLimit: 255
      EcuAddressComment: ""
    EcuAddressExtension: []
      CalibrationAccess: 'Calibration'
      DisplayIdentifier: ""
                 Format: ""
                BitMask: []
               AxisInfo: []
           RecordLayout: ""
             Dimensions: []
                 Export: 1
             MaxRefresh: [1x1 struct]
             SymbolLink: [1x1 struct]
             CustomData: ""

To modify a property of the characteristic, use set function. Update the UpperLimit field of the characteristic.

set(descObj,"Characteristic","Custom_parameter1",UpperLimit=128)

Generate the ASAP2 file using the updated ECU description object and verify that the ASAP2 file contains the characteristic Custom_parameter1.

coder.asap2.export("ASAP2Demo",CustomEcuDescriptions=descObj);
Following Characteristics or Measurements with unsupported data types are not exported in ASAP2 file. "ASAP2Demo_DW.ASAP2DemoModelRef_InstanceData"

Remove the newly added characteristic from the description object.

delete(descObj,"Characteristic","Custom_parameter1");

Create and Add Custom Measurement

To add a new measurement to the ASAP2 file, create a custom measurement.

Signal_1 = coder.asap2.Measurement;
Signal_1.Name = 'Custom_signal1';
Signal_1.LongIdentifier = 'longIdentifierSignal';
Signal_1.UpperLimit = 255;
Signal_1.LowerLimit = 0;

Add the custom measurement to the ECU description object.

add(descObj,Signal_1);

Get the properties of the newly added measurement.

get(descObj,"Measurement","Custom_signal1")
ans = 
  Measurement with properties:

                   Name: 'Custom_signal1'
         LongIdentifier: 'longIdentifierSignal'
               DataType: 'UBYTE'
             EcuAddress: '0x0000'
        CompuMethodName: ""
             LowerLimit: 0
             UpperLimit: 255
                 Raster: [1x1 struct]
      EcuAddressComment: ""
    EcuAddressExtension: []
      CalibrationAccess: 'NoCalibration'
      DisplayIdentifier: ""
                 Format: ""
                BitMask: []
             Dimensions: []
                 Export: 1
               MaskData: [1x1 struct]
             MaxRefresh: [1x1 struct]
             SymbolLink: [1x1 struct]
             CustomData: ""

To modify a property of the measurement, use set function. Update the CalibrationAccess field of the measurement.

set(descObj,"Measurement","Custom_signal1",CalibrationAccess='Calibration')

Generate the ASAP2 file using the updated ECU description object and verify that the ASAP2 file contains the measurement with name Custom_signal1.

coder.asap2.export("ASAP2Demo",CustomEcuDescriptions=descObj);
Following Characteristics or Measurements with unsupported data types are not exported in ASAP2 file. "ASAP2Demo_DW.ASAP2DemoModelRef_InstanceData"

Remove the newly added measurement from the description object.

delete(descObj,"Measurement","Custom_signal1");

Create and Add Lookup Table Parameter

Add a lookup table parameter.

LUT_Parameter = coder.asap2.Characteristic;
LUT_Parameter.Name = "custom_lookup_table";
LUT_Parameter.Type = "MAP";

Create and add axis information to the parameter.

axis_data = coder.asap2.AxisInfo;
axis_data(1).Name = 'BP3';
axis_data(2).Name = 'Bp4';
axis_data(1).CompuMethodName = 'ASAP2Demo_CM_double';
axis_data(2).CompuMethodName = 'ASAP2Demo_CM_double';
axis_data(1).MaxAxisPoints = '3';
axis_data(2).MaxAxisPoints = '3';
axis_data(1).AxisType = 'STD_AXIS';
axis_data(2).AxisType = 'STD_AXIS';
LUT_Parameter.AxisInfo = axis_data;

Add the lookup table parameter to the description object.

add(descObj,LUT_Parameter)

Generate the ASAP2 file using the updated ECU description object and verify that the ASAP2 file contains the lookup table parameter custom_lookup_table.

coder.asap2.export("ASAP2Demo",CustomEcuDescriptions=descObj);
Following Characteristics or Measurements with unsupported data types are not exported in ASAP2 file. "ASAP2Demo_DW.ASAP2DemoModelRef_InstanceData"

Version History

Introduced in R2022b