supply variable efficiency map to a hydraulic pump

1 view (last 30 days)
Hi All,
How can I input an efficiency map instead of a fixed value parameter for the fixed-displacement hydraulic pump model in simhydraulics?
Any ideas?

Answers (1)

Yifeng Tang
Yifeng Tang on 16 Jun 2022
In newer versions of Simscape Fluids, the fixed-displacement pumps allow lookup tables as inputs to specify the efficiency as a function of pressure gain and rpm.
If those are not available to you, the way to implement this manually is via lookup table outside ideal source blocks. A diagram like below can be a starting point. It only cover the volumetric efficiency part and requires RPM as a signal input.
If you want to couple it with the mechanical domain, as in the fixed-displacement pump block, you may add a torque source and a velocity sensor for that purposes. The input to the torque source will be calculated from the delta_P and mechanical efficiency lookup table. The output from the velocity sensor will be sent to the "pump".

Categories

Find more on Upgrading Hydraulic Models to Use Isothermal Liquid Blocks in Help Center and File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!