Pressure Relief Valve

Pressure control valve maintaining preset pressure in system

Library

Pressure Control Valves

Description

The Pressure Relief Valve block represents a hydraulic pressure relief valve as a data-sheet-based model. The following figure shows the typical dependency between the valve passage area A and the pressure differential p across the valve.

The valve remains closed while pressure at the valve inlet is lower than the valve preset pressure. When the preset pressure is reached, the valve control member (spool, ball, poppet, etc.) is forced off its seat, thus creating a passage between the inlet and outlet. Some fluid is diverted to a tank through this orifice, thus reducing the pressure at the inlet. If this flow rate is not enough and pressure continues to rise, the area is further increased until the control member reaches its maximum. At this moment, the maximum flow rate is passing through the valve. The value of a maximum flow rate and the pressure increase over the preset level to pass this flow rate are generally provided in the catalogs. The pressure increase over the preset level is frequently referred to as valve steady state error, or regulation range. The valve maximum area and regulation range are the key parameters of the block.

In addition to the maximum area, the leakage area is also required to characterize the valve. The main purpose of the parameter is not to account for possible leakage, even though this is also important, but to maintain numerical integrity of the circuit by preventing a portion of the system from getting isolated after the valve is completely closed. An isolated or "hanging" part of the system could affect computational efficiency and even cause failure of computation. Theoretically, the parameter can be set to zero, but it is not recommended.

By default, the block does not include valve opening dynamics, and the valve sets its opening area directly as a function of pressure:

A=A(p)

Adding valve opening dynamics provides continuous behavior that is more physically realistic, and is particularly helpful in situations with rapid valve opening and closing. The pressure-dependent orifice passage area A(p) in the block equations then becomes the steady-state area, and the instantaneous orifice passage area in the flow equation is determined as follows:

A(t=0)=Ainit

dAdt=A(p)Aτ

In either case, the flow rate through the valve is determined according to the following equations:

q=CDA2ρp(p2+pcr2)1/4

p=pApB

pcr=ρ2(RecrνCDDH)2

A(p)={Aleakfor p<=psetAleak+k·(ppset)for pset<p<pmaxAmaxfor p>=pmax

k=AmaxAleakpreg

DH=4Aπ

where

qFlow rate
pPressure differential
pA, pBGauge pressures at the block terminals
CDFlow discharge coefficient
AInstantaneous orifice passage area
A(p)Pressure-dependent orifice passage area
AinitInitial open area of the valve
AmaxFully open valve passage area
AleakClosed valve leakage area
pregRegulation range
psetValve preset pressure
pmaxValve pressure at maximum opening
ρFluid density
νFluid kinematic viscosity
τTime constant for the first order response of the valve opening
tTime
pcrMinimum pressure for turbulent flow
RecrCritical Reynolds number
DHValve instantaneous hydraulic diameter

The block positive direction is from port A to port B. This means that the flow rate is positive if it flows from A to B and the pressure differential is determined as p=pApB.

Basic Assumptions and Limitations

  • Valve opening is linearly proportional to the pressure differential.

  • No loading on the valve, such as inertia, friction, spring, and so on, is considered.

Dialog Box and Parameters

Maximum passage area

Valve passage maximum cross-sectional area. The default value is 1e-4 m^2.

Valve pressure setting

Preset pressure level, at which the orifice of the valve starts to open. The default value is 50e5 Pa.

Valve regulation range

Pressure increase over the preset level needed to fully open the valve. MathWorks recommends using values less than 0.2 of the Valve pressure setting parameter value. The default value is 5e5 Pa.

Flow discharge coefficient

Semi-empirical parameter for valve capacity characterization. Its value depends on the geometrical properties of the orifice, and usually is provided in textbooks or manufacturer data sheets. The default value is 0.7.

Critical Reynolds number

The maximum Reynolds number for laminar flow. The transition from laminar to turbulent regime is assumed to take place when the Reynolds number reaches this value. The value of the parameter depends on the orifice geometrical profile. You can find recommendations on the parameter value in hydraulics textbooks. The default value is 12.

Leakage area

The total area of possible leaks in the completely closed valve. The main purpose of the parameter is to maintain numerical integrity of the circuit by preventing a portion of the system from getting isolated after the valve is completely closed. An isolated or "hanging" part of the system could affect computational efficiency and even cause simulation to fail. Therefore, MathWorks recommends that you do not set this parameter to 0. The default value is 1e-12m^2.

Opening dynamics

Select one of the following options:

  • Do not include valve opening dynamics — The valve sets its orifice passage area directly as a function of pressure. If the area changes instantaneously, so does the flow equation. This is the default.

  • Include valve opening dynamics — Provide continuous behavior that is more physically realistic, by adding a first-order lag during valve opening and closing. Use this option in hydraulic simulations with the local solver for real-time simulation. This option is also helpful if you are interested in valve opening dynamics in variable step simulations.

Opening time constant

The time constant for the first order response of the valve opening. This parameter is available only if Opening dynamics is set to Include valve opening dynamics. The default value is 0.1 s.

Initial area

The initial opening area of the valve. This parameter is available only if Opening dynamics is set to Include valve opening dynamics. The default value is 1e-12 m^2.

 Restricted Parameters

Global Parameters

Parameters determined by the type of working fluid:

  • Fluid density

  • Fluid kinematic viscosity

Use the Hydraulic Fluid block or the Custom Hydraulic Fluid block to specify the fluid properties.

Ports

The block has the following ports:

A

Hydraulic conserving port associated with the valve inlet.

B

Hydraulic conserving port associated with the valve outlet.

Examples